Skip to content

Industries / Critical Infrastructure & OT

Power, gas, water, and the
control networks behind them.

Generation plants, gas distribution, water and wastewater, pipelines, and the cooperatives and public utility districts that run them. Our practitioners assessed refineries, pipelines, and nuclear networks for the U.S. Army before Sentinel existed. We test the IT side like an attacker and the OT side like someone who knows what a tripped breaker costs.

NERC CIPTSA PIPELINE SECURITY DIRECTIVESNIST SP 800-82IEC 62443AWIACISA CPGs
$4.83M
Average cost of a data breach in the energy sector
29%
Of ransomware incidents at energy, oil/gas, and utility providers began with phishing
CIP
NERC reliability standards for the bulk electric system, with mandatory penalties
TSA SD
Security Directives requiring pipeline operators to assess and segment OT

SOURCES: IBM COST OF A DATA BREACH REPORT 2025 · SOPHOS, THE STATE OF RANSOMWARE 2025 · NERC CIP · TSA PIPELINE SECURITY DIRECTIVES

Why infrastructure

In OT, the finding is not data loss. It is an outage.

Utilities run two networks that were never meant to touch: a corporate IT environment that looks like any business, and a control environment built decades ago for uptime, not authentication. The attacks that matter cross from one to the other through a historian, a vendor VPN, an engineering laptop, or a jump host nobody owns.

Most firms test the IT side and stop at the firewall. We scope the boundary itself: how a phished office account becomes HMI access, which remote-support paths bypass the DMZ, and whether the PLC network would notice. Done safely, with the operators in the room, inside windows you set.

We sell no software, no monitoring, and no remediation. The report is the only product. Hardening and integration work goes back to your engineers or your integrator.

Obligations

The standards an operator answers to.

NERC CIP-002 THROUGH CIP-015

Bulk electric system

Asset categorization, electronic security perimeters, access management, and the evidence an auditor expects for each. Testing scoped to low-, medium-, and high-impact BES cyber systems as appropriate.

TSA SECURITY DIRECTIVES

Pipelines & gas

Network segmentation between IT and OT, access control, continuous monitoring, and patching requirements for designated pipeline and LNG operators.

NIST SP 800-82

OT security baseline

The reference for assessing industrial control systems without breaking them: architecture, zones and conduits, and compensating controls.

IEC 62443

Zones, conduits & security levels

Assessment against target security levels for plant networks, and the gap between the design and what is actually on the wire.

AWIA §2013

Water & wastewater

Risk and resilience assessment and emergency response plan requirements for community water systems, on a recurring certification cycle.

CISA CPGs

Cross-sector goals

The baseline federal and state programs use for cooperatives and public utility districts outside NERC or TSA scope.

Threats

How IT compromise becomes OT impact.

01

Ransomware that reaches operations

Encryption on the corporate side forcing a precautionary shutdown of control systems that were supposed to be isolated.

02

Remote access abuse

Vendor and engineer VPNs, cellular modems, and remote-support tools that land directly on the control network.

03

Dual-homed hosts

Historians, engineering workstations, and jump servers that bridge IT and OT without anyone treating them as the boundary.

04

Legacy protocols and defaults

Modbus, DNP3, and vendor web interfaces with no authentication, reachable from further away than the diagram says.

Scope

What we test in an infrastructure environment.

Electric generation and distribution cooperatives, public utility districts, municipal utilities, gas distribution, pipeline operators, water and wastewater systems, and the engineering firms that serve them.

IT / OT boundary

The DMZ, firewalls, data diodes, and every host that touches both sides.

Remote access

Vendor VPNs, remote-support tools, cellular and radio links, and who can reach what from outside.

SCADA, HMI & historians

Authentication, exposure, and the paths from a workstation to a control screen. Passive and safe-active methods, agreed in advance.

Control networks

PLC and RTU segments, protocol exposure, and whether segmentation holds under an attacker who already has a foothold.

Corporate IT & Active Directory

Where most incidents start: phishing, lateral movement, and privilege escalation toward engineering accounts.

Customer-facing systems

Billing portals, outage maps, payment processors, and AMI head-ends.

Physical & substations

Access to plants, substations, pump stations, and the network ports inside them.

Social engineering

Phishing and pretexting against operators, dispatchers, and vendors with standing access.

Process

Safety first, then adversary realism.

OT testing follows a written safety plan agreed with operations. Passive discovery by default on control networks; active techniques only where you approve them, in a maintenance window, with an operator watching the process.

01

Scope & safety plan

Assets, zones, no-touch lists, windows, written authorization, fixed price.

02

Reconnaissance

External footprint, remote-access paths, exposed OT services.

03

IT exploitation

Validated attack paths toward the boundary.

04

Boundary & OT assessment

Crossing demonstrated to the agreed stopping point, never past it.

05

Reporting

Findings mapped to CIP, TSA, 800-82, or 62443 as they apply.

06

Retest

Closure verified at no added cost.

Deliverables

Written for the compliance manager, the plant manager, and the board.

  • Findings report with reproducible evidence, severity ratings, and the IT-to-OT path drawn end to end
  • Standards crosswalk mapping each finding to NERC CIP, TSA directives, NIST 800-82, or IEC 62443 requirements
  • Executive and board briefing in operational terms: what could have stopped, for how long
  • Prioritized remediation roadmap that respects outage windows and vendor constraints
  • Retest included, verifying closure in writing

Find out how far a phished email could travel toward the plant.

Each engagement is scoped individually with a written safety plan and quoted at a fixed price. We respond within one business day.

Request a quote