Industries / Critical Infrastructure & OT
Power, gas, water, and the
control networks behind them.
Generation plants, gas distribution, water and wastewater, pipelines, and the cooperatives and public utility districts that run them. Our practitioners assessed refineries, pipelines, and nuclear networks for the U.S. Army before Sentinel existed. We test the IT side like an attacker and the OT side like someone who knows what a tripped breaker costs.
SOURCES: IBM COST OF A DATA BREACH REPORT 2025 · SOPHOS, THE STATE OF RANSOMWARE 2025 · NERC CIP · TSA PIPELINE SECURITY DIRECTIVES
Why infrastructure
In OT, the finding is not data loss. It is an outage.
Utilities run two networks that were never meant to touch: a corporate IT environment that looks like any business, and a control environment built decades ago for uptime, not authentication. The attacks that matter cross from one to the other through a historian, a vendor VPN, an engineering laptop, or a jump host nobody owns.
Most firms test the IT side and stop at the firewall. We scope the boundary itself: how a phished office account becomes HMI access, which remote-support paths bypass the DMZ, and whether the PLC network would notice. Done safely, with the operators in the room, inside windows you set.
We sell no software, no monitoring, and no remediation. The report is the only product. Hardening and integration work goes back to your engineers or your integrator.
Obligations
The standards an operator answers to.
Bulk electric system
Asset categorization, electronic security perimeters, access management, and the evidence an auditor expects for each. Testing scoped to low-, medium-, and high-impact BES cyber systems as appropriate.
Pipelines & gas
Network segmentation between IT and OT, access control, continuous monitoring, and patching requirements for designated pipeline and LNG operators.
OT security baseline
The reference for assessing industrial control systems without breaking them: architecture, zones and conduits, and compensating controls.
Zones, conduits & security levels
Assessment against target security levels for plant networks, and the gap between the design and what is actually on the wire.
Water & wastewater
Risk and resilience assessment and emergency response plan requirements for community water systems, on a recurring certification cycle.
Cross-sector goals
The baseline federal and state programs use for cooperatives and public utility districts outside NERC or TSA scope.
Threats
How IT compromise becomes OT impact.
Ransomware that reaches operations
Encryption on the corporate side forcing a precautionary shutdown of control systems that were supposed to be isolated.
Remote access abuse
Vendor and engineer VPNs, cellular modems, and remote-support tools that land directly on the control network.
Dual-homed hosts
Historians, engineering workstations, and jump servers that bridge IT and OT without anyone treating them as the boundary.
Legacy protocols and defaults
Modbus, DNP3, and vendor web interfaces with no authentication, reachable from further away than the diagram says.
Scope
What we test in an infrastructure environment.
Electric generation and distribution cooperatives, public utility districts, municipal utilities, gas distribution, pipeline operators, water and wastewater systems, and the engineering firms that serve them.
IT / OT boundary
The DMZ, firewalls, data diodes, and every host that touches both sides.
Remote access
Vendor VPNs, remote-support tools, cellular and radio links, and who can reach what from outside.
SCADA, HMI & historians
Authentication, exposure, and the paths from a workstation to a control screen. Passive and safe-active methods, agreed in advance.
Control networks
PLC and RTU segments, protocol exposure, and whether segmentation holds under an attacker who already has a foothold.
Corporate IT & Active Directory
Where most incidents start: phishing, lateral movement, and privilege escalation toward engineering accounts.
Customer-facing systems
Billing portals, outage maps, payment processors, and AMI head-ends.
Physical & substations
Access to plants, substations, pump stations, and the network ports inside them.
Social engineering
Phishing and pretexting against operators, dispatchers, and vendors with standing access.
Process
Safety first, then adversary realism.
OT testing follows a written safety plan agreed with operations. Passive discovery by default on control networks; active techniques only where you approve them, in a maintenance window, with an operator watching the process.
Scope & safety plan
Assets, zones, no-touch lists, windows, written authorization, fixed price.
Reconnaissance
External footprint, remote-access paths, exposed OT services.
IT exploitation
Validated attack paths toward the boundary.
Boundary & OT assessment
Crossing demonstrated to the agreed stopping point, never past it.
Reporting
Findings mapped to CIP, TSA, 800-82, or 62443 as they apply.
Retest
Closure verified at no added cost.
Deliverables
Written for the compliance manager, the plant manager, and the board.
- Findings report with reproducible evidence, severity ratings, and the IT-to-OT path drawn end to end
- Standards crosswalk mapping each finding to NERC CIP, TSA directives, NIST 800-82, or IEC 62443 requirements
- Executive and board briefing in operational terms: what could have stopped, for how long
- Prioritized remediation roadmap that respects outage windows and vendor constraints
- Retest included, verifying closure in writing
Find out how far a phished email could travel toward the plant.
Each engagement is scoped individually with a written safety plan and quoted at a fixed price. We respond within one business day.